有用5520A做谐波表校准源的吗
上次遇到一个要测谐波电流的,看了5520A说明书,捣鼓半天没成功。有高人弄过没,指点一二。使用方波输出就可以了
不过因为平均值是0, 所以只有奇次谐波,且谐波含量的百分比不能调整. 我过去经常用9100校准谐波表,标准值是9100给出的,用傅立叶变换也可以计算出来.( 现在有6100,就不用这种方法了.)数据如下:谐波次数 标准输入值(%) 显示值(%)
1 90.032 90.2
3 29.999 30.1
5 17.988 18.0
7 12.830 12.9
9 9.967 10.0
11 8.139 8.2
13 6.866 7.0
15 5.933 6.1
17 5.379 5.3
19 4.650 4.8
21 4.190 4.1
23 3.808 3.9 需要有5520的功率选件(PQ)。
预置IEC A, IEC D等谐波,也可自己定义各次谐波的分量。
Nominal Amplitude and Phase Values for Preinstalled IEC A Composite Harmonic Waves
Wave Harmonic % of Fundamental Phase
1st 100.0 % 0°
2nd 47.00 % 0°
3rd 100.00 % 180.0°
4th 18.70 % 180.0°
5th 49.60 % 0°
6th 13.00 % 0°
7th 33.50 % 180.0°
8th 10.00 % 180.0°
9th 17.40 % 0°
10th 8.00 % 0°
11th 14.30 % 180.0°
12th 6.67 % 180.0°
13th 9.13 % 0°
14th 5.71 % 0°
15th 6.52 % 180.0°
16th 5.00 % 180.0°
17th 5.75 % 0°
18th 4.44 % 0°
19th 5.15 % 180.0°
20th 4.00 % 180.0°
21st 4.66 % 0°
22nd 3.64 % 0°
23rd 4.25 % 180.0°
24th 3.33 % 180.0°
25th 3.91 % 0°
26th 3.08 % 0°
27th 3.62 % 180.0°
28th 2.86 % 180.0°
29th 3.37 % 0°
30th 2.67 % 0°
31st 3.16 % 180.0°
32nd 2.50 % 180.0°
IEC A
33rd 2.96 % 0°
34th 2.35 % 0°
35th 2.80 % 180.0°
36th 2.22 % 180.0°
37th 2.64 % 0°
38th 2.11 % 0°
39th 2.51 % 180.0°
40th 2.00 % 180.0° 电流,电压用方波输出 lgum 发表于 2008-3-22 13:24
电流,电压用方波输出
这是啥意思呀,双输出吗,频率都是方波吗 一种方式是 双电压输出功能:
输出时接5520的两个高端,比如在面板上同时输入10V,1V 50Hz,正弦波,然后有一个谐波菜单,可以调节谐波的次数。
另一种方法是输出方波:
比如Fluke43B的校准方法就是,输出一个2.5V,60Hz的方波,然后看被校表的波形及参数。 threemore 发表于 2015-9-11 17:21
一种方式是 双电压输出功能:
输出时接5520的两个高端,比如在面板上同时输入10V,1V 50Hz,正弦波,然后有 ...
能再详细说一下操作吗? 双电压输出吗?
接线: Normal的 Hi端 -------->被检表
AUX的Hi端------------->被检表。
输出按键:10V,1V,50Hz
软件操作:harmonic-->,进入以后可以调节谐波次数。
页: