平晶检定时干涉条纹的快速调整方法与平面度计算
宫美望 刘文君青岛市计量测试所,山东青岛266071
青岛市水利勘测设计院有限公司,山东青岛266023
摘 要:在平面等厚干涉仪上检定平晶工作面平面度时,需要在被检区域调整出3到5条干涉条纹,依据测量原理和计算公式求出被检平晶工作面的平面度。文章重点分析干涉条纹的快速调整方法与标准平晶平面度的正确引用方法。[著者文摘]
Quick-adjusting Method of Interference Fringes and Flatness Calculation of Optical Flat Working SurfaceGONG Mei-wang, LIU Wen-jun 1. Qingdao Institute of Measurement and Testing , Qingdao 266071, China; 2. Qingdao Water Conservancy Survey Design Institute Limited Company, Qingdao 266023, ChinaAbstract:Flatness of optical flat working surface was verified by use of plane equal-thickness interferometer. In verification, 3 to 5 interference fringes must be adjusted in measured area, then flatness of optical flat working surface was calcuylated based on measuring principle and foroula. Quick adjusting method of interference fringes and correct quotation method of standard optical flat flatness are analyzed.[著者文摘]
Key words:equal-thickness interference; interference fringe; adjusting method; flatness; calculation 看了上传的《平晶检定时干涉条纹的快速调整方法与平面度计算》一文,感觉作者还是下了一定功夫的。现对文章中关于平晶检定得出的平面度结果“符合最小条件原则”的说辞,以及标准平晶F96平面度的计算问题,暂时先不去评论。仅针对文章中“被检区域出现3到5条干涉条纹”的说法,“咬文嚼字”的谈一点个人看法:
在平面等厚干涉仪上检定工作平晶平面度时,文章中谈到调整后平面等厚干涉仪的视场中“出现3到5条干涉条纹”,这“3到5条”极易让人从字面上理解为3至5条、3~5条,也就是讲在3、5数字之间还有4,这与规程JJG 28—2000的文字描述是有字面及内容上的较大不同的,规程中对被检区域出现的干涉条纹是这样描述的“3或5”,也就是从字面上理解只能为整数3或者5,肯定不包括整数4。被检平晶的干涉条纹只能为奇数3或5,其道理非常好理解,也就是保证干涉条纹间距成像基本清晰,便于平面等厚干涉仪指标线瞄准读数的基础上,保证中间的干涉条纹通过被检平晶的最大直径上。
道理不必细谈了,“咬文嚼字”是为了测量原理及方法的正确无误,所以文字描述必须严谨。 有道理,学习了 有道理,值得借鉴